QuadroM32x/8L/26x/12Li/26xi Manual II: Administrator's Guide Administrator’s Menus
QuadroM32x/8L/26x/12Li/26xi; (SW Version 5.3.x)
Enable Redundancy
checkbox is used to enable the
redundancy functionality on the Quadro.
Active Device Mode drop down list is only present on backup
device and is used to adjust the behavior of the backup device
during unavailability of master device. When Active is
selected, backup device will become master once the original
master device became unavailable. When Passive is
selected, backup device stops its synchronization with the
master device and will not take over the control even when the
original master got failed unless Swap Master Device button
is pressed on the master Quadro. The Passive mode is used
for firmware update or language pack updates on master
device when a reboot is required. After the reboot of master
device, the Active Device Mode on the backup device should
be changed back to Active to restore the redundant network
functionality.
Fig. II-75: Redundancy Settings list
Redundant Group ID text field unique ID (values 1 and up) identifying master and backup devices. The same value must be set on both Quadros.
Virtual IP Address text fields require the virtual IP address of the device where the configuration is done. Virtual Subnet Mask text fields require
the virtual subnet mask of the device where the configuration is done. These two parameters identify an alternate IP network of the LAN interface
which stays unchanged when the device switches its mode (from master to backup or vice versa). The configuration and voice data synchronization
daemon uses this IP address to communicate with the second Quadro.
Redundant Device Virtual IP Address text fields require an alternate IP address of the LAN interface of the second Quadro.
Synchronization Interval text field requires the period of time (in seconds) between two consecutive configuration and voice data synchronizations
from master to backup device.
Backup Device GUI Access Port text field is present on the master device only and requires the port used for accessing the GUI of the backup
device through master.
Swap Master Device button is used for manual swapping of functionality of master and backup devices. This action will result in rebooting the
current master. After rebooting the current master device will start running in a backup mode. Switching the backup to master starts all applications
on Quadro and causes all IP phones to reboot. The swapping takes around 1 minute however another 1-3 minutes are required in order to reboot all
the IP phones connected to redundant system. If backup device before swapping was in passive mode then after swapping the master will start
running as backup in passive mode, otherwise if it was in active mode then master will start running as backup in active mode.
Download system logs link is only present on backup device and is used to download system logs to the local PC as a *.tar archive file. These logs
can then be used by the
Epygi Technical Support Office to determine the problem that has occurred on your Quadro.